Electrical Installation Condition Reports

EICR Testing in London for Landlords, Homeowners & Businesses

Book a professional inspection of your property's fixed wiring, consumer unit, circuits, earthing and protective devices. Receive a clear digital Electrical Installation Condition Report with test results, classification codes and practical next steps.

Book an EICR
Why EICR Matters FAQ
⚡ EICR Guide for London Properties

EICR Testing in London: Checks, Results and Requirements

An Electrical Installation Condition Report (EICR) checks a property’s fixed wiring, consumer unit, circuits, earthing and protective devices. It gives landlords, homeowners, buyers, sellers and businesses a clear record of the installation’s condition and any action required.

London coverage Clear digital report Practical next steps
EICR at a glance
Inspection Fixed wiring and safety protection
Result Satisfactory or unsatisfactory
Report Test results, codes and next steps

PAT testing is a separate service for portable appliances.

01 Definition

What Is an EICR?

A formal condition report for the fixed electrical installation already inside the property.

  • Assesses safety, deterioration and defects
  • Records inspection limits and observations
  • Recommends the next inspection date
02 Who It Helps

Who Needs an EICR?

  • Landlords: electrical safety duties
  • Homeowners: older or altered wiring
  • Buyers & sellers: clearer property information
  • Businesses: planned electrical maintenance
03 Your Report

What Will You Receive?

  • A satisfactory or unsatisfactory outcome
  • Inspection schedules and electrical test results
  • C1, C2, C3 or FI observations
  • Clear next steps where action is needed
Inspection scope

What Does an EICR Inspection Cover?

Accessible and agreed parts of the fixed installation are visually inspected and tested.

01

Consumer Unit

Condition, circuit identification and protective devices.

02

Circuits & Wiring

Continuity, insulation, polarity and deterioration.

03

Sockets & Switches

Accessible accessories and fixed electrical equipment.

04

Earthing & Bonding

Protection intended to reduce electric-shock risk.

05

RCD Protection

Operation and suitability of protective devices.

06

Damage & Risks

Overheating, overloading and unsafe alterations.

For Private and Social Rented Homes in England

Three Landlord Essentials

Always check the report date and the next-inspection date stated by the inspector.

5 years

Routine Interval

At least every five years, or sooner if the report requires.

28 days

Provide the Report

Give an existing tenant a copy within 28 days.

28 days

Complete Required Action

Or sooner where the report states a shorter period.

General guidance for England. Read the official guidance .

Inspection limitations

What an EICR Does Not Include

An EICR is a condition report for accessible parts of the fixed electrical installation. It does not automatically include destructive access, appliance testing or repair work.

  • Concealed cables are not automatically exposed
  • Walls, ceilings and floors are not opened unless separately agreed
  • Portable appliances require separate equipment testing
  • Repairs and remedial work are not included
  • Inaccessible areas are recorded as limitations
  • Specialist systems may require separate assessment
What happens on the day

A Clear Four-Step Inspection

Simple for the customer, detailed where electrical safety matters.

  1. 01

    Confirm Access

    Property details, access and agreed inspection scope.

  2. 02

    Visual Inspection

    Condition, damage, labelling and protective measures.

  3. 03

    Electrical Testing

    Instrument tests on circuits and safety devices.

  4. 04

    Report & Advice

    Results, coded observations and practical next steps.

Before the appointment

How to Prepare for Your EICR

A few simple steps help the inspection run safely and efficiently.

  • Provide access to the consumer unit
  • Make sockets and electrical points accessible
  • Safely shut down sensitive equipment
  • Inform tenants about temporary power interruptions
  • Provide any previous EICR or electrical certificates
  • Tell us about alarms, medical equipment or essential power requirements
Plain-English report codes

Understanding Your EICR Results

Under the current model form, C1 and C2 affect the overall satisfactory or unsatisfactory assessment. FI remains important and, for regulated rented homes, any required further investigation must still be completed within the applicable legal timeframe.

C1

Danger Present

Immediate action required.

C2

Potentially Dangerous

Urgent action required.

FI

Further Investigation

Additional checks required.

C3

Improvement Recommended

Safety improvement advised.

Next steps after the report

What Happens If Your EICR Is Unsatisfactory?

An unsatisfactory result means safety-related action is required. The report remains part of the property record while the observations are investigated and addressed.

C1

Immediate Safety Action

C1 dangers are made safe or addressed immediately.

C2

Urgent Remedial Work

C2 defects require urgent remedial work.

FI

Further Investigation

FI observations require additional investigation.

£

Separate Quotation

A separate quotation is provided before remedial work begins.

Completion Evidence

Appropriate certification confirms completed remedial work.

Property Record

The original EICR remains part of the property’s electrical record.

Transparent EICR pricing

Residential EICR Packages in London

Indicative package prices are confirmed in writing after the property, circuit count and consumer-unit details are checked.

Studio / Bedsit
£99
Indicative package price
  • Up to 6 circuits
  • 1 consumer unit
  • Digital report in 24–48 hours
Request Package Quote
3–4 Bedrooms
£159
Indicative package price
  • Up to 12 circuits
  • 1 consumer unit
  • Digital report in 24–48 hours
Request Package Quote
5–6 Bedrooms
From £199
Price confirmed before booking
  • Up to 16 circuits
  • 1 consumer unit
  • Digital report in 24–48 hours
Request a Fixed Quote
Commercial & HMO EICR — From £199 Quoted by circuit count, boards, access and installation complexity. Request a Quote
Included Inspection, electrical testing and digital EICR report.
Additional items Extra circuits from £15 each; additional consumer units from £45.
Not included Remedial work, repairs or replacement parts.
VAT status & travel costs Electro Conduct is not currently VAT registered, so VAT is not charged on or added to the displayed prices.

Prices shown are indicative until the property details are checked and confirmed in writing. Final pricing depends on accurate information, safe access and the stated circuit and consumer-unit limits. Additional work is never added without approval. No VAT will be added while Electro Conduct is not VAT registered.

Professional EICR testing across London

Clear Inspection. Clear Report. Clear Next Steps.

Send your postcode, property type, bedroom count, consumer-unit count and estimated circuits.

Why EICR Matters

Electrical Risks an EICR Can Identify

An EICR checks fixed wiring and protective devices to identify hidden safety, fire and compliance risks.

Warning signs: repeated tripping, flickering lights, hot sockets, scorch marks, buzzing or burning smells should not be ignored.

Personal safety Shock and Burn Risks

Electrical faults can expose occupants, tenants, employees and visitors to dangerous electrical contact.

  • Damaged insulation or exposed conductors can increase the risk of electric shock and electrical burns.
  • Inadequate earthing or bonding may prevent fault current from being safely directed away.
  • RCDs and circuit breakers are tested to check whether suitable fault protection is present and operating correctly.
Fire prevention Fire and Overheating Risks

Electrical heat can build up gradually before visible damage or a more serious electrical incident occurs.

  • Loose electrical connections can create resistance, excessive heat and burning at terminals.
  • Overloaded or poorly protected circuits may overheat when demand exceeds their safe capacity.
  • Hot sockets, scorch marks and burning smells can indicate conditions requiring urgent investigation.
Hidden condition Deteriorated or Altered Wiring

A property can appear normal while faults are developing behind walls, ceilings, accessories or consumer units.

  • Cables, connections and accessories can deteriorate through age, heat, wear, damage or environmental conditions.
  • Extensions and converted rooms may place additional demand on circuits not designed for their current use.
  • DIY work or previous alterations can leave poor connections, incorrect protection or unsuitable wiring arrangements.
Property and compliance Compliance and Unexpected Repair Costs

Early identification helps landlords, homeowners and businesses plan work before it becomes urgent or disruptive.

  • Most rented homes in England require an electrical inspection at least every five years, with required work completed within the stated timescale.
  • Homeowners, buyers and property managers receive clearer information for maintenance, budgeting and property decisions.
  • Businesses and commercial properties can reduce the risk of unexpected power loss, emergency repairs and operational disruption.

Safety information informed by London Fire Brigade , NICEIC and GOV.UK landlord guidance .

Updated EICR Guidance

EICR Questions, Answered Clearly

Practical answers about EICR pricing, inspection time, power interruptions, report codes, landlord responsibilities and remedial work in London.

Classification wording updated for BS 7671:2018+A4:2026

The current model form states that C1 and C2 affect the overall assessment, while C3 and FI are advisory. Separate legal duties can still require landlords to complete further investigation.

01 How much does an EICR cost in London?

Residential EICR packages currently start at £99 for a studio or bedsit, £129 for a one- or two-bedroom property, £159 for three or four bedrooms, and from £199 for larger homes. The final price is confirmed after checking circuit count, consumer units, access, parking and Congestion Charge requirements. Commercial and HMO properties are quoted separately. Remedial work is not included, and any applicable VAT or additional charges are shown before booking.

02 How long does an EICR inspection take?

A typical residential EICR takes around one to three hours, but larger, older or more complex installations can take longer. The duration depends on the number of circuits and consumer units, access to electrical points, previous alterations and whether faults are discovered during testing. Commercial and HMO inspections usually require more time. We confirm the likely appointment length after reviewing the property details and agreed inspection scope.

03 Will the electricity need to be switched off during an EICR?

Yes, short power interruptions are normally required because several EICR tests must be carried out on isolated circuits. The electrician will explain when supplies need to be switched off and will try to minimise disruption. Sensitive equipment, computers, alarms and appliances should be shut down safely beforehand. If continuous power is essential for medical, business or security reasons, tell us before the appointment so the inspection can be planned appropriately.

04 What does an EICR inspection check?

An EICR checks the accessible and agreed parts of the fixed electrical installation, including consumer units, circuits, fixed wiring, sockets, switches, light fittings, earthing, bonding, RCDs and other protective devices. Testing may cover continuity, insulation resistance, polarity, earth-fault loop impedance and RCD operation. Concealed cables and inaccessible areas are not automatically opened up; the report records the inspection extent, agreed limitations and any items that could not be verified.

05 What do C1, C2, C3 and FI mean on an EICR in 2026?

Under the current BS 7671:2018+A4:2026 model form, C1 means danger is present and immediate remedial action is necessary. C2 identifies a potentially dangerous condition requiring urgent action. C3 means improvement is recommended, while FI means further investigation is advised. These codes help prioritise the findings: C1 and C2 affect the overall assessment, whereas C3 and FI provide important advisory information about improvements or checks still needed.

06 Does an FI code make an EICR unsatisfactory?

No. An FI observation does not by itself make the model EICR form unsatisfactory. It means the inspector could not confirm the safety or condition of a specific part of the installation without additional investigation. FI should still be treated seriously. For regulated rented homes in England, any further investigation required by the report must generally be completed within 28 days, or sooner where the report states a shorter deadline.

07 What happens if an EICR is unsatisfactory?

An unsatisfactory EICR means safety-related work is required before the installation can be treated as satisfactory. The next step is to obtain a clear remedial quotation, complete the necessary work and keep evidence that each observation has been addressed. Depending on the repair, this may include an Electrical Installation Certificate, Minor Electrical Installation Works Certificate or written remedial confirmation. The original EICR remains part of the property’s electrical safety record.

08 Is remedial work included in the EICR price?

No. EICR remedial work is normally priced separately from the inspection and report. The EICR identifies and classifies observations; it does not automatically authorise repairs, replacement parts or further investigation. Where action is required, Electro Conduct can provide a separate quotation explaining the work and cost before proceeding. For landlords in England, required remedial or investigative work must usually be completed within 28 days, or within any shorter period stated in the report.

09 When will I receive the EICR report?

Digital EICR reports are normally issued within 24 to 48 hours after the inspection, provided the test schedules and observations can be completed without additional investigation. More complex commercial, HMO or multi-board installations may take longer. If a C1 danger is found, the person ordering the report should be informed without delay rather than waiting for the final document. The completed report includes the overall assessment, observations, classification codes, test results and recommended next-inspection date.

10 How often do landlords need an EICR in England?

For most rented homes in England, the electrical installation must be inspected and tested by a qualified person at least every five years, or sooner if the report specifies an earlier date. The existing tenant must receive the report within 28 days, and a new tenant must receive it before occupation. Required remedial or further investigative work must generally be completed within 28 days, or within any shorter period stated in the report.

11 Is a new EICR required every time the tenant changes?

Usually not. If the existing inspection was completed within the required interval, the report remains current and it does not require further investigative or remedial work, a new EICR is generally not needed for every change of tenant in England. The landlord must give the new tenant a copy before occupation. A fresh inspection may still be sensible if the installation has been altered, damaged or gives reason to believe it is no longer safe.

12 Is an EICR the same as PAT testing?

No. An EICR assesses the fixed electrical installation, such as wiring, consumer units, circuits, sockets, switches, earthing and protective devices. PAT or in-service equipment testing concerns portable or supplied electrical equipment and is a separate process. One does not replace the other. The correct combination depends on the property, the equipment provided, the type of occupancy and any landlord or workplace responsibilities that apply to the premises.

13 What information is needed for an EICR quote?

To confirm the correct EICR package, provide the property postcode, property type, number of bedrooms, number of consumer units or distribution boards and an estimated circuit count if known. Also mention HMO or commercial use, restricted access, parking controls, the Congestion Charge Zone and any need to maintain essential power. These details help us confirm whether a package price applies or whether a tailored fixed quotation is required before booking.

14 How should I prepare the property for an EICR?

Before the appointment, make sure the electrician can reach the consumer unit, sockets, switches and other agreed electrical points. Safely shut down computers, alarms and sensitive equipment that may be affected by temporary power interruptions. Provide any previous EICRs or electrical certificates if available, inform tenants or occupants about the visit, and tell the electrician in advance about medical equipment, essential power supplies or restricted-access areas.

Technical wording follows the IET BS 7671:2018+A4:2026 model EICR form . Landlord timelines refer to current GOV.UK guidance for England .

Need an EICR price for your property?

Send the postcode, property type, bedroom count, consumer-unit count and estimated number of circuits for an accurate package or fixed quotation.